T1 Mapping for the Diagnosis of Acute Myocarditis Using CMR

 
δείτε την πρωτότυπη σελίδα τεκμηρίου
στον ιστότοπο του αποθετηρίου του φορέα για περισσότερες πληροφορίες και για να δείτε όλα τα ψηφιακά αρχεία του τεκμηρίου*
κοινοποιήστε το τεκμήριο



T1 Mapping for the Diagnosis of Acute Myocarditis Using CMR

Piechnik, Stefan K.
Friedrich, Matthias G.
Dall'Armellina, Erica
Robson, Matthew D.
Neubauer, Stefan
Holloway, Cameron
Kardos, Attila
Choudhury, Robin P.
Ntusi, Ntobeko
Ferreira, Vanessa M.
Karamitsos, Theodoros
Francis, Jane M.

OBJECTIVES: This study sought to test the diagnostic performance of native T1 mapping in acute myocarditis compared with cardiac magnetic resonance (CMR) techniques such as dark-blood T2-weighted (T2W)-CMR, bright-blood T2W-CMR, and late gadolinium enhancement (LGE) imaging. BACKGROUND: The diagnosis of acute myocarditis on CMR often requires multiple techniques, including T2W, early gadolinium enhancement, and LGE imaging. Novel techniques such as T1 mapping and bright-blood T2W-CMR are also sensitive to changes in free water content. We hypothesized that these techniques can serve as new and potentially superior diagnostic criteria for myocarditis. METHODS: We investigated 50 patients with suspected acute myocarditis (age 42 ± 16 years; 22% women) and 45 controls (age 42 ± 14 years; 22% women). CMR at 1.5-T (median 3 days from presentation) included: 1) dark-blood T2W-CMR (short-tau inversion recovery); 2) bright-blood T2W-CMR (acquisition for cardiac unified T2 edema); 3) native T1 mapping (shortened modified look-locker inversion recovery); and 4) LGE. Image analysis included: 1) global T2 signal intensity ratio of myocardium compared with skeletal muscle; 2) myocardial T1 relaxation times; and 3) areas of LGE. RESULTS: Compared with controls, patients had significantly higher global T2 signal intensity ratios by dark-blood T2W-CMR (1.73 ± 0.27 vs. 1.56 ± 0.15, p < 0.01), bright-blood T2W-CMR (2.02 ± 0.33 vs. 1.84 ± 0.17, p < 0.01), and mean myocardial T1 (1,010 ± 65 ms vs. 941 ± 18 ms, p < 0.01). Receiver-operating characteristic analysis showed clear differences in diagnostic performance. The areas under the curve for each method were: T1 mapping (0.95), LGE (0.96), dark-blood T2 (0.78), and bright-blood T2 (0.76). A T1 cutoff of 990 ms had a sensitivity, specificity, and diagnostic accuracy of 90%, 91%, and 91%, respectively. CONCLUSIONS: Native T1 mapping as a novel criterion for the detection of acute myocarditis showed excellent and superior diagnostic performance compared with T2W-CMR. It also has a higher sensitivity compared with T2W and LGE techniques, which may be especially useful in detecting subtle focal disease and when gadolinium contrast imaging is not feasible. Copyright © 2013. Published by Elsevier Inc.

Article / Άρθρο
info:eu-repo/semantics/article

Αριστοτέλειο Πανεπιστήμιο Θεσσαλονίκης (EL)
Aristotle University of Thessaloniki (EN)

Αγγλική γλώσσα

2016-10-11T09:20:09Z
2013


Αριστοτέλειο Πανεπιστήμιο Θεσσαλονίκης, Σχολή Επιστημών Υγείας, Τμήμα Ιατρικής

JACC: Cardiovascular Imaging, vol.6 no.10 [2013] p.1048-1058
urn:ISSN:1936878X

This record is part of 'IKEE', the Institutional Repository of Aristotle University of Thessaloniki's Library and Information Centre found at http://ikee.lib.auth.gr. Unless otherwise stated above, the record metadata were created by and belong to Aristotle University of Thessaloniki Library, Greece and are made available to the public under Creative Commons Attribution-ShareAlike 4.0 International license (http://creativecommons.org/licenses/by-sa/4.0). Unless otherwise stated in the record, the content and copyright of files and fulltext documents belong to their respective authors. Out-of-copyright content that was digitized, converted, processed, modified, etc by AUTh Library, is made available to the public under Creative Commons Attribution-ShareAlike 4.0 International license (http://creativecommons.org/licenses/by-sa/4.0). You are kindly requested to make a reference to AUTh Library and the URL of the record containing the resource whenever you make use of this material.
info:eu-repo/semantics/openAccess



*Η εύρυθμη και αδιάλειπτη λειτουργία των διαδικτυακών διευθύνσεων των συλλογών (ψηφιακό αρχείο, καρτέλα τεκμηρίου στο αποθετήριο) είναι αποκλειστική ευθύνη των αντίστοιχων Φορέων περιεχομένου.