Nafion and Polylysine treated PEDOT mammalian cell biosensor [article]

 
δείτε την πρωτότυπη σελίδα τεκμηρίου
στον ιστότοπο του αποθετηρίου του φορέα για περισσότερες πληροφορίες και για να δείτε όλα τα ψηφιακά αρχεία του τεκμηρίου*
κοινοποιήστε το τεκμήριο




2011 (EL)

Nafion and Polylysine treated PEDOT mammalian cell biosensor [article]

Flampouria, E.
Kintzios, S.

The present study describes a cell-based biosensor utilizing PEDOT electrodes coated with Nafion and polylysine for combined conductivity, cellular adhesion and proliferation. Neuroblastoma N2a cells were seeded on top of PEDOT electrodes treated with Nafion and Polylysine. Cellular attachment and viability were assayed and chronoamperometric measurements were taken to evaluate H202 toxicity. Cells exhibited relatively hight viability compared to those seeded in tissue culture plates. Chronoamperometric responses also provided preliminary evidence of the possible use of this assembly as a toxicity biosensor.

Text (Journal article, Conference or workshop item (Paper))
Text

κυτταρολογία
ηλεκτροχημεία
βιοτεχνολογία


Αγγλική γλώσσα

2011-09

ISSN: 1877-7058
DOI: 10.1016/j.proeng.2011.12.240

Procedia Engineering, 25 (2011): 976 – 979 και Proc. Eurosensors XXV, September 4-7, 2011, Athens, Greece




*Η εύρυθμη και αδιάλειπτη λειτουργία των διαδικτυακών διευθύνσεων των συλλογών (ψηφιακό αρχείο, καρτέλα τεκμηρίου στο αποθετήριο) είναι αποκλειστική ευθύνη των αντίστοιχων Φορέων περιεχομένου.