Self-expanding metallic stent placement with an exaggerated 5-cm proximal tumor covering for palliation of esophageal cancer

 
Το τεκμήριο παρέχεται από τον φορέα :

Αποθετήριο :
Annals of Gastroenterology
δείτε την πρωτότυπη σελίδα τεκμηρίου
στον ιστότοπο του αποθετηρίου του φορέα για περισσότερες πληροφορίες και για να δείτε όλα τα ψηφιακά αρχεία του τεκμηρίου*
κοινοποιήστε το τεκμήριο




2015 (EL)

Self-expanding metallic stent placement with an exaggerated 5-cm proximal tumor covering for palliation of esophageal cancer (EN)

Ferraro, Pasquale
Berthiaume, Melanie
Thiffault, Vicky
Tahiri, Mehdi
Duranceau, André
Liberman, Moishe

Background The study aimed to evaluate the short- and long-term outcomes with a technique of self-expanding metallic stent insertion in palliative esophageal cancer patients. We hypothesized that a systematic attempt at exaggerated (5 cm) proximal tumor covering could prevent both stent migration and tumor overgrowth/undergrowth.Methods We reviewed retrospectively all patients who underwent esophageal stenting for palliation of malignant dysphagia over a 24-month period. Consecutive patients were identified from a prospective thoracic surgery interventional endoscopy database. This technique consisted of endoscopic stent insertion with the aim of landing the proximal portion of the stent 5 cm cephalad to the proximal extent of the tumor. All patients were followed at one month post-procedure and every three months thereafter, until death. Short- and long-term complications associated with the procedure and mortality were evaluated.Results Forty seven patients underwent endoscopic insertion of an esophageal stent in the context of an inoperable esophageal cancer using this technique over a 24-month period. The mean age was 70.4±9.6 years. Four (8.5%) patients underwent re-stenting due to proximal tumor overgrowth. No stent migration, perforation, tumor ingrowth or stent occlusion was reported. The mean patient survival was 146±26.5 days.Conclusions Esophageal stent insertion under endoscopic guidance with proximal tumor covering of 5 cm is effective and safe. No cases of stent migration and a low incidence of tumor overgrowth/undergrowth were observed with this technique.Keywords Esophageal stent, self-expanding metallic stent, esophageal cancer, migration, tumor overgrowth, tumor ingrowthAnn Gastroenterol 2015; 28 (3): 345-350 (EN)

info:eu-repo/semantics/article
info:eu-repo/semantics/publishedVersion


Αγγλική γλώσσα

2015-06-11


Hellenic Society of Gastroenterology (EN)

1792-7463
1108-7471
Annals of Gastroenterology; Volume 28, No 3 (2015); 347 (EN)




*Η εύρυθμη και αδιάλειπτη λειτουργία των διαδικτυακών διευθύνσεων των συλλογών (ψηφιακό αρχείο, καρτέλα τεκμηρίου στο αποθετήριο) είναι αποκλειστική ευθύνη των αντίστοιχων Φορέων περιεχομένου.