Impact of Full Spectrum Endoscopy® (Fuse®, EndoChoice®) on adenoma detection: a prospective French pilot study

 
Το τεκμήριο παρέχεται από τον φορέα :

Αποθετήριο :
Annals of Gastroenterology
δείτε την πρωτότυπη σελίδα τεκμηρίου
στον ιστότοπο του αποθετηρίου του φορέα για περισσότερες πληροφορίες και για να δείτε όλα τα ψηφιακά αρχεία του τεκμηρίου*
κοινοποιήστε το τεκμήριο




2017 (EL)

Impact of Full Spectrum Endoscopy® (Fuse®, EndoChoice®) on adenoma detection: a prospective French pilot study (EN)

Hoibian, Solene
De Cassan, Chiara
Giovannini, Marc
Caillol, Fabrice
Bories, Erwan
Lestelle, Valentin
Casanova, Jean-Patrick
Ratone, Jean-Philippe
Pesenti, Christian
Servajean, Cécilia
Landon, Marine
Poizat, Flora
Godat, Sébastien
Sellier, Floriane

Background Currently, colonoscopy and polypectomy are the gold standard methods for the prevention of incident cases of colorectal cancer. The use of a new colonoscope (Fuse, EndoChoice®) with a larger view of up to 330° appears to improve the adenoma detection rate (ADR). We performed a prospective observational study concerning this scope. The primary endpoint was potentially omitted adenomas (POA), i.e. adenomas seen on the side screens that will not appear on the central display during colonoscopy withdrawal without oriented movements. Secondary endpoints included our ADR, Fuse® impact on ADR, time to cecal intubation and withdrawal time.Methods We performed a single-center prospective study in one French center. We enrolled patients over 18 years of age between January 2015 and March 2016.Results We included 141 patients; 3 were excluded because their colonoscopies were incomplete. Our study included 78 men and 60 women (sex ratio 1.3). The mean age was 60.4 years. A total of 130 polyps were resected. In all, 88/130 were adenomas (68%) and 34/88 adenomas (39%) were POA. The mean time to cecum was 10 min, and the mean withdrawal time was 12 min. ADR was 35% for men and 31% for women. The estimated ADR without POA was 29% for men and 19% for women.Conclusions The Fuse® system appears to be safe and efficient. POA represented 39% of all adenomas. The impact of the panoramic view on the ADR was considered substantial. The main limitations are the lack of randomization and the absence of a control group.Keywords Panoramic view, adenoma detection rate, missed adenomasAnn Gastroenterol 2017; 30 (5): 512-517 (EN)

info:eu-repo/semantics/article
info:eu-repo/semantics/publishedVersion


Αγγλική γλώσσα

2017-08-23


Hellenic Society of Gastroenterology (EN)

1792-7463
1108-7471
Annals of Gastroenterology; Volume 30, No 5 (2017); 512 (EN)




*Η εύρυθμη και αδιάλειπτη λειτουργία των διαδικτυακών διευθύνσεων των συλλογών (ψηφιακό αρχείο, καρτέλα τεκμηρίου στο αποθετήριο) είναι αποκλειστική ευθύνη των αντίστοιχων Φορέων περιεχομένου.