A thermal accelerometer directly integrated on organic substrate

 
This item is provided by the institution :
Technological Educational Institute of Athens
Repository :
Ypatia - Institutional Repository
see the original item page
in the repository's web site and access all digital files if the item*
share




2011 (EN)
A thermal accelerometer directly integrated on organic substrate (EN)

Πετρόπουλος, Αναστάσιος (EL)
Αθηναίος, Σπύρος Σ. (EL)
Καλτσάς, Γρηγόριος (EL)
Μόσχος, Αναστάσιος (EL)

N/A (EN)

A thermal accelerometer was developed and evaluated. The presented device was fabricated directly on an organic substrate, which ensures a high level of thermal isolation, while also facilitating direct electrical communication to the macroworld. The role of the seismic mass was utilized by a fluid (water), which was confined in a tank adjusted on the sensor surface. Acceleration quantification is achieved by the monitoring of the cooling effect on the heating element. A sensor signal of 32mV for an acceleration of 1g was obtained. (EN)

journalArticle

Sensor surfaces (EN)
Convective thermal accelerometer (EN)
Επιφάνειες αισθητήρα (EN)
Organic substrate (EN)
Σήματα αισθητήρα (EN)
Μεταφερόμενο θερμικό επιταχυνσιόμετρο (EN)
Sensor signals (EN)
Οργανικό υπόστρωμα (EN)

ΤΕΙ Αθήνας (EL)
Technological Educational Institute of Athens (EN)

Procedia Engineering (EN)

English

2011

DOI: 10.1016/j.proeng.2011.12.160

Elsevier (EN)



*Institutions are responsible for keeping their URLs functional (digital file, item page in repository site)