The attenuation evolution near notch tips in polymers by the NDT method of ultrasounds

 
δείτε την πρωτότυπη σελίδα τεκμηρίου
στον ιστότοπο του αποθετηρίου του φορέα για περισσότερες πληροφορίες και για να δείτε όλα τα ψηφιακά αρχεία του τεκμηρίου*
κοινοποιήστε το τεκμήριο




1992 (EL)

The attenuation evolution near notch tips in polymers by the NDT method of ultrasounds (EN)

Theotokoglou, EN (EN)
Prassianakis, JN (EN)

The influence of singularities on the evolution of ultrasound attenuation for materials was studied experimentally. The specimens used were made of plexiglas. They were prismatic with or without an edge crack, normal to the edge, or a V-shaped notch. The specimens were loaded in tension gradually until fracture. The load level and the degree of the singularity correlated experimentally to the degree of ultrasound attenuation. An ultrasonic pulse echo signal was used to investigate and measure the degree of attenuation, for the ultrasonic stress wave propagating through the stressed specimens. © 1992. (EN)

journalArticle (EN)

Stresses (EN)
Macroscopic Failure (EN)
Nondestructive Examination (EN)
NDT Method (EN)
Plexiglas (EN)
Ultrasonic Stress (EN)
Numerical Methods (EN)
Ultrasonics (EN)
Ultrasounds (EN)
Fracture Mechanics (EN)
Attenuation Evolution (EN)
Mechanics (EN)
Notch Tip (EN)
Polymers (EN)


Engineering Fracture Mechanics (EN)

Αγγλική γλώσσα

1992 (EN)

121 (EN)
1 (EN)
0013-7944 (EN)
117 (EN)
ISI:A1992JJ49800012 (EN)
43 (EN)

PERGAMON-ELSEVIER SCIENCE LTD (EN)




*Η εύρυθμη και αδιάλειπτη λειτουργία των διαδικτυακών διευθύνσεων των συλλογών (ψηφιακό αρχείο, καρτέλα τεκμηρίου στο αποθετήριο) είναι αποκλειστική ευθύνη των αντίστοιχων Φορέων περιεχομένου.