δείτε την πρωτότυπη σελίδα τεκμηρίου στον ιστότοπο του αποθετηρίου του φορέα για περισσότερες πληροφορίες και για να δείτε όλα τα ψηφιακά αρχεία του τεκμηρίου*
Current achievements of the DELPHI ring imaging Cherenkov detector
(EN)
Baillon, P
(EN)
Buys, A
(EN)
Fokitis, E
(EN)
Carrie, P
(EN)
Katsoufis, E
(EN)
Schyns, E
(EN)
Lenzen, G
(EN)
Davenport, M
(EN)
Stassi, P
(EN)
Katsanevas, S
(EN)
Sannino, M
(EN)
Ilie, S
(EN)
Dimitriou, N
(EN)
Markou, A
(EN)
Poutot, D
(EN)
Delbecque, F
(EN)
Reale, M
(EN)
Traspedini, L
(EN)
Toet, DZ
(EN)
Albrecht, E
(EN)
Dahl-Jensen, E
(EN)
Huet, K
(EN)
Koene, B
(EN)
Fontenille, A
(EN)
Thadome, J
(EN)
D'Almagne, B
(EN)
Bloch, D
(EN)
Gazis, EN
(EN)
Kjaer, N
(EN)
Polok, G
(EN)
Hahn, F
(EN)
Michalowski, J
(EN)
Juillot, P
(EN)
Christophel, E
(EN)
Aubret, C
(EN)
Montano, F
(EN)
Cavalli, P
(EN)
Ekelof, T
(EN)
Filippas, TA
(EN)
Papadopoulou, ThD
(EN)
Nielsen, BS
(EN)
Engel, JP
(EN)
Dris, M
(EN)
Gillespie, D
(EN)
Tobar, MJ
(EN)
Zevgolatakos, E
(EN)
Rahmani, H
(EN)
Andrieux, M-L
(EN)
Furstenau, H
(EN)
Gracco, V
(EN)
Strub, R
(EN)
Guglielmi, L
(EN)
Brunet, JM
(EN)
Kourkoumelis, C
(EN)
Garcia, J
(EN)
Dolbeau, J
(EN)
Fontanelli, F
(EN)
Hao, W
(EN)
Lopez Aguera, A
(EN)
Loukas, D
(EN)
Mourgue, G
(EN)
Fraissard, D
(EN)
Lindqvist, L-E
(EN)
Botner, O
(EN)
Dracos, M
(EN)
Ioannou, P
(EN)
Kluit, PM
(EN)
Karvelas, E
(EN)
Ullaland, O
(EN)
Lecoeur, G
(EN)
Sajot, G
(EN)
Nicolaidou, R
(EN)
Tripodi, G
(EN)
Joram, C
(EN)
Battaglia, M
(EN)
Fassouliotis, D
(EN)
Damgaard, G
(EN)
Chevry, M
(EN)
Hallgren, A
(EN)
Maltezos, S
(EN)
Medbo, J
(EN)
Cerutti, G
(EN)
Petrolini, A
(EN)
Adam, W
(EN)
Jaaskelainen, S
(EN)
Theodosiou, GE
(EN)
Bourdarios, C
(EN)
Squarcia, S
(EN)
Van Apeldoorn, G
(EN)
Haider, S
(EN)
Tsirou, A
(EN)
Allen, D
(EN)
Tristram, G
(EN)
Augustinus, A
(EN)
Resvanis, LK
(EN)
The DELPHI experiment has already collected 2.5 million Z(0) decays with the ring imaging Cherenkov detector (RICH) operational. This detector, covering most of the solid angle, is designed to perform pi/K separation from 0.8 to 20 GeV/c and K/p separation from 0.8 to 35 GeV/c. After a brief detector description we discuss the actual operating conditions, the data monitoring and the signal treatment. The collected data from Z(0) decays and the detector response to signals from the calibration system are used to evaluate the performance of the RICH system.
(EN)
*Η εύρυθμη και αδιάλειπτη λειτουργία των διαδικτυακών διευθύνσεων των συλλογών (ψηφιακό αρχείο, καρτέλα τεκμηρίου στο αποθετήριο) είναι αποκλειστική ευθύνη των αντίστοιχων Φορέων περιεχομένου.
Βοηθείστε μας να κάνουμε καλύτερο το OpenArchives.gr.