Ion-pair single-drop microextraction versus phase-transfer catalytic extraction for the gas chromatographic determination of phenols as tosylated derivatives

 
Το τεκμήριο παρέχεται από τον φορέα :

Αποθετήριο :
Ιδρυματικό Αποθετήριο Ολυμπιάς
δείτε την πρωτότυπη σελίδα τεκμηρίου
στον ιστότοπο του αποθετηρίου του φορέα για περισσότερες πληροφορίες και για να δείτε όλα τα ψηφιακά αρχεία του τεκμηρίου*
κοινοποιήστε το τεκμήριο




2008 (EL)

Ion-pair single-drop microextraction versus phase-transfer catalytic extraction for the gas chromatographic determination of phenols as tosylated derivatives (EN)

Fiamegos, Y. C. (EN)

Πανεπιστήμιο Ιωαννίνων. Σχολή Θετικών Επιστημών. Τμήμα Χημείας (EL)
Fiamegos, Y. C. (EN)

The environmental fate of phenols represents a diachronic scientific consideration mainly due to their high toxicity and diverse physicochemical properties rendering them difficult to be analyzed as unity. Ion-pair-assisted extraction and microextraction techniques in association with a dedicated derivatization reaction are possible to lead to enhanced selectivity and sensitivity in gas chromatography. Phase-transfer catalytic liquid-liquid extraction-derivatization and ion-pair-assisted single-drop microextraction with in-drop derivatization are successfully employed for the analysis of 15 phenolic compounds. The analytes that react at room temperature with p-toluenesulfonyl chloride into the bulk of the organic phase are subsequently determined by GC-MS in selective-ion monitoring mode. Aiming at maximizing the derivatization yields obtained from the 15 analytes in a reasonable time period, the optimum experimental parameters were established along with the figures of merit of the methods. The limits of detection ranged from 0.48 to 1.5 ng/ml and from 0.20 to 0.28 ng/ml respectively, while the limits of quantitation ranged from 1.4 to 4.5 ng/ml and from 0.59 to 0.84 ng/ml for the two methods with the techniques under study. The overall procedure presented satisfactory analytical features with the liquid-liquid extraction protocol being easier to carry out while the single-drop one, presented higher sensitivity and significant reduction of the organic solvent employed. By comparison with other methods for the analysis of phenols, the proposed methods exhibit adequately low detection limits, good precision, short derivatization time and low solvent, sample and reagent consumption. (C) 2008 Elsevier B.V. All rights reserved. (EN)

phenols (EN)


Journal of Chromatography A (EN)

Αγγλική γλώσσα

2008


Elsevier (EN)




*Η εύρυθμη και αδιάλειπτη λειτουργία των διαδικτυακών διευθύνσεων των συλλογών (ψηφιακό αρχείο, καρτέλα τεκμηρίου στο αποθετήριο) είναι αποκλειστική ευθύνη των αντίστοιχων Φορέων περιεχομένου.