Validity of the usefulness of microvascular architecture and microsurface structure using magnifying endoscopy with narrow-band imaging in the colorectal neoplasm

 
This item is provided by the institution :

Repository :
Annals of Gastroenterology
see the original item page
in the repository's web site and access all digital files if the item*
share




2012 (EN)

Validity of the usefulness of microvascular architecture and microsurface structure using magnifying endoscopy with narrow-band imaging in the colorectal neoplasm (EN)

Hisabe, Takashi
Yao, Kenshi
Ninomiya, Kazeo
Nagahama, Takashi
Hirai, Fimihito
Tanabe, Hiroshi
Beppu, Takahiro
Takaki, Yasuhiro
Matsui, Toshiyuki
Iwashita, Akinori

Background Magnifying endoscopy (ME) with narrow-band imaging (NBI) has been described as useful in diagnosing colorectal neoplasms. However, there is no standardized simple classification system, and its usefulness in comparison with pit pattern diagnosis by magnifying chromoendoscopy (MC) is unclear. The aim of this study was to investigate the usefulness of evaluations of microvascular architecture (MV) and microsurface structure (MS) by ME with NBI in the diagnosis of colorectal neoplasms.Methods A total of 360 colorectal neoplasms were analyzed by retrospective analysis of prospectively collected data. The vessel plus surface (VS) classification system was applied for ME with NBI diagnosis. The main outcome measurement was comparison of the diagnostic performance of ME with NBI and MC.Results The sensitivity of ME with NBI and MC for the diagnosis of adenomas was 91.9% and 95.7%, respectively, and their specificity was 79.2% and 79.9%, respectively. The sensitivity of ME with NBI and MC for the diagnosis of cancer was 70.5% and 79.9%, respectively, and the specificity was 95.3% and 95.7%, respectively. The sensitivity of ME with NBI and MC for the diagnosis of cancer with deep submucosal invasion was 50.0% and 88.0%, respectively (P < 0.0001), and their specificity was 100% and 82.8%, respectively (P < 0.0001).Conclusions The specificity of evaluation of MV and MS by ME with NBI for the diagnosis of cancer with deep submucosal invasion was much higher than that of pit pattern analysis by MC.Keywords Magnifying endoscopy, narrow-band imaging, colorectal neoplasm, cancer (EN)

info:eu-repo/semantics/article
info:eu-repo/semantics/publishedVersion


English

2012-12-21


Hellenic Society of Gastroenterology (EN)

1792-7463
1108-7471
Annals of Gastroenterology; Volume 26, No 1 (2013); 45 (EN)




*Institutions are responsible for keeping their URLs functional (digital file, item page in repository site)