Neutrons along the labyrinth of high energy medical accelerators: Effect of wall materials

see the original item page
in the repository's web site and access all digital files if the item*



Neutrons along the labyrinth of high energy medical accelerators: Effect of wall materials (EN)

Kalef-Ezra, J.
Stamatelatos, I. E.
Fakinou, M.

info:eu-repo/semantics/article
info:eu-repo/semantics/publishedVersion

2019-03-08


Neutron streaming along the labyrinth of a generic bunker of an 18MV medical accelerator was evaluated. Monte Carlo simulations using MCNP code were performed to calculate neutron ambient dose equivalent along the labyrinth. The effect of plain, borated and barites concrete wall material, as well as borated concrete and plywood (Celotex), as neutron absorbing wall liners, was examined. The results of the study suggest that plywood can provide a cost effective material to attenuate neutron streaming along the labyrinth. (EN)


Medical Accelerator (EN)
Monte Carlo simulations (EN)
Neutron streaming (EN)
Radiation Shielding (EN)

Annual Symposium of the Hellenic Nuclear Physics Society

English

Hellenic Nuclear Physics Society (HNPS) (EN)


2654-0088
2654-007X
Annual Symposium of the Hellenic Nuclear Physics Society; Τόμ. 21 (2013): HNPS2013; 169-171 (EL)
HNPS Advances in Nuclear Physics; Vol. 21 (2013): HNPS2013; 169-171 (EN)

Πνευματική ιδιοκτησία (c) 2019 M. Fakinou, I. E. Stamatelatos, J. Kalef-Ezra (EL)