GEANT4/GATE Simulation Studies in the Emission Tomography

Το τεκμήριο παρέχεται από τον φορέα :
Hellenic Nuclear Physics Society   

Αποθετήριο :
Annual Symposium of the Hellenic Nuclear Physics Society  | ΕΚΤ eProceedings   

δείτε την πρωτότυπη σελίδα τεκμηρίου
στον ιστότοπο του αποθετηρίου του φορέα για περισσότερες πληροφορίες και για να δείτε όλα τα ψηφιακά αρχεία του τεκμηρίου*



GEANT4/GATE Simulation Studies in the Emission Tomography (EN)

Apostolopoulou, S.
Zioga, M.
Menis, J.
Maintas, D.
Mikeli, M.
Nikopoulou, A.
Rapsomanikis, A.-N.
Stiliaris, E.

info:eu-repo/semantics/article
info:eu-repo/semantics/publishedVersion

2020-01-01


Radiotracer imaging studies for a small field, high resolution ∞-Camera system and a clinical system for Positron Emission Tomography (PET) by means of GATE (GEANT4 Application for Tomographic Emission) simulations are presented in this work. In a validation phase, which preceded the main study, experimentally obtained results for planar images with the existing ∞-Camera system were directly compared to simulated data. A simple phantom structure, consisting of four parallel capillaries filled with 99mTc water solution, was imaged by the γ-Camera system for several phantom-collimator distances and the measured and Monte-Carlo calculated spatial projections were compared. The major objective of this validation study was the optimal description of the most important components, the hexagonal, parallel-hole Pb-collimator and the pixelated CsI scintillation crystal of the γ-imaging system in terms of GATE components. In the main study, a GATE simulation setup for this ∞-Camera detector is used and Monte-Carlo data are accumulated for simple geometrical phantoms with different monophotonic radiotracer energies and relative intensities. In parallel, a commercially available cylindrical shaped PET scanner ring, consisting of 32 sectors with 4 x 6 x 6 LSO scintillation crystals, has been constructed in the GATE environment. Simulation data are obtained for the most usual positron emitters (18F, 11C and 15O) and for several phantom geometries. The spatial resolution of both systems and their overall performance is presented and discussed in this study. (EN)


GEANT4 (EN)
SPECT (EN)
PET (EN)
γ-Camera (EN)
Monte-Carlo Simulation (EN)

Annual Symposium of the Hellenic Nuclear Physics Society

Αγγλική γλώσσα

Hellenic Nuclear Physics Society (HNPS) (EN)


2654-0088
2654-007X
Annual Symposium of the Hellenic Nuclear Physics Society; Τόμ. 19 (2011): HNPS2011; 50-54 (EL)
HNPS Advances in Nuclear Physics; Vol. 19 (2011): HNPS2011; 50-54 (EN)

Πνευματική ιδιοκτησία (c) 2019 M. Zioga, J. Menis, S. Apostolopoulou, D. Maintas, M. Mikeli, A. Nikopoulou, A.-N. Rapsomanikis, E. Stiliaris (EL)




*Η εύρυθμη και αδιάλειπτη λειτουργία των διαδικτυακών διευθύνσεων των συλλογών (ψηφιακό αρχείο, καρτέλα τεκμηρίου στο αποθετήριο) είναι αποκλειστική ευθύνη των αντίστοιχων Φορέων περιεχομένου.