Luminol chemiluminescense reaction: a new method for monitoring nitric oxide in vivo

 
This item is provided by the institution :

Repository :
Repository of UOI Olympias
see the original item page
in the repository's web site and access all digital files if the item*
share




2002 (EN)

Luminol chemiluminescense reaction: a new method for monitoring nitric oxide in vivo (EN)

Yao, D. C. (EN)

Πανεπιστήμιο Ιωαννίνων. Σχολή Θετικών Επιστημών. Τμήμα Χημείας (EL)
Yao, D. C. (EN)

A new method employing a combination of microdialysis sampling and chemiluminescence (CL) detection was developed to monitor nitric oxide (NO) in vivo. A special probe was designed with an interference-free membrane to achieve very high selectivity for NO. High sensitivity was achieved by optimizing the working system and improving the NO sampling time. This system was used in vivo to monitor blood and brain tissue in rats and rabbits. The system is sensitive enough to detect variations of NO formation under different physiological states. The linear valid range of NO determination is 5 nM to 1 muM, with a 3sigma detection limit of I nM; real NO concentrations in test animals used in this work were found to be in the range of 1-5 nM or even less. Finally, the effects of body temperature, NO donors, Viagra, NO activators, NO cofactors and NO interference (such as O-2) were investigated carefully in different physiological situations. (C) 2002 Elsevier Science B.V. All rights reserved. (EN)

nitric oxide (EN)


Analytica Chimica Acta (EN)

English

2002


Elsevier Masson (EN)