Efficacy and safety of lumen-apposing metal stent for benign gastrointestinal stricture

This item is provided by the institution :
Hellenic Society of Gastroenterology   

Repository :
Annals of Gastroenterology   

see the original item page
in the repository's web site and access all digital files if the item*



Efficacy and safety of lumen-apposing metal stent for benign gastrointestinal stricture (EN)

Singhal, Shashideep
Ali, Sara
Patel, Upen
Sharma, Abhinav
Shah, Manan
Jain, Deepanshu

info:eu-repo/semantics/article
info:eu-repo/semantics/publishedVersion

2018-07-02


Management of benign gastrointestinal (GI) strictures refractory to primary (balloon and savary dilation) and secondary (steroid injection, fully covered self-expanding metal stent, incision therapy) treatment modalities remains a challenge. Lumen-apposing metal stents (LAMSs), originally designed for the management of pancreatic fluid collections, are an attractive option for GI stricture because of their anti-migratory property, attributable to their saddle-shaped design. In this article, we reviewed 70 patients from 12 original studies who received LAMS for refractory (68/70) or treatment-naïve (2/70) benign GI stricture. The technical and clinical success rates were 98.6% (69/70) and 79.7% (55/69), respectively. Endoscopic placement, with or without fluoroscopic guidance, was generally successful, with only a minority requiring endoscopic ultrasound (EUS) guidance where the lumen was completely obscured. The majority of the strictures were short (≤1 cm), but comparable technical and clinical success was noted in isolated cases with long strictures, where 2 overlapping LAMSs were placed. For the overall population, a failure rate of 21.5% (14/69) was noted and was attributed to either lack of follow up, or to persistent or de novo symptoms requiring stent removal/exchange or surgical referral. One perforation (1.4%), five stent migration events (7.1%), two bleeding events (2.9%) and two de novostrictures proximal to the LAMS (2.9%) were reported for the entire study cohort. No mortality was attributable to LAMS placement. Although experience is still evolving, LAMS placement guided by esophagogastroduodenoscopy or EUS is a technically feasible and safe procedure with good clinical outcomes for benign refractory GI strictures. Keywords Benign stricture, gastrointestinal stricture, lumen-apposing metal stent Ann Gastroenterol 2018; 31 (4): 425-438 (EN)


English

Hellenic Society of Gastroenterology (EN)


1792-7463
1108-7471
Annals of Gastroenterology; Volume 31, No 4 (2018); 425 (EN)

Copyright (c) 2018 Annals of Gastroenterology (EN)




*Institutions are responsible for keeping their URLs functional (digital file, item page in repository site)