Continuous versus pulsed microwave ablation in the liver: any difference in intraoperative pain scores?

Το τεκμήριο παρέχεται από τον φορέα :
Ελληνική Γαστροεντερολογική Εταιρία   

Αποθετήριο :
Annals of Gastroenterology   

δείτε την πρωτότυπη σελίδα τεκμηρίου
στον ιστότοπο του αποθετηρίου του φορέα για περισσότερες πληροφορίες και για να δείτε όλα τα ψηφιακά αρχεία του τεκμηρίου*



Continuous versus pulsed microwave ablation in the liver: any difference in intraoperative pain scores? (EN)

Mazioti, Argyro
Filippiadis, Dimitrios
Kelekis, Nikolaos
Tsoxatzis, Athanasios
Velonakis, George
Tosoratti, Nevio
Kelekis, Alexis

info:eu-repo/semantics/article
info:eu-repo/semantics/publishedVersion

2021-01-04


Background This study prospectively compared intraoperative pain scores during percutaneous microwave ablation of the liver in patients randomized between continuous and pulsed energy delivery algorithms. Methods During a 12-month period, 20 patients who underwent microwave liver ablation were prospectively randomized between 2 different energy delivery modes: “continuous mode” (CM, n=10) and “pulsed mode” (PM, n=10). All ablation sessions were performed using the same microwave ablation platform under computed tomographic guidance and intravenous analgesia. Within 30 min post ablation, all patients completed a questionnaire assigning a numeric pain intensity score from 0 (no pain) to 10. Results Mean pain scores were 8.17±1.850 in the CM group and 4.50±1.567 in the PM group, with a statistically significant difference of 3.667±2.807 pain units (P=0.001). The mean procedure time was 53.5±20.90 min in the PM group vs. 58.5±17.44 min in the CM group (P=0.279). The mean size of the lesions was 2.81±0.95 cm in the PM group and 2.81±0.85 cm in the CM group (P=0.984). On a per-lesion basis, technical success was achieved in all evaluable tumors in both groups. No difference was noted in the local tumor control on the 6-month imaging evaluation. No complications were observed in the CM arm, while small perihepatic hemorrhagic fluid collections were reported in the PM group. Conclusions Both algorithms for microwave energy delivery have comparable treatment effects in terms of 6-month local tumor control for liver lesions <3 cm in diameter. PM treatments compared to CM appear to induce significantly less pain in patients undergoing percutaneous liver ablation under intravenous analgesia. Keywords Microwave ablation, continuous, pulsed, percutaneous, liver Ann Gastroenterol 2021; 34 (1): 80-84 (EN)


Αγγλική γλώσσα

Hellenic Society of Gastroenterology (EN)


1792-7463
1108-7471
Annals of Gastroenterology; Volume 34, No 1 (2021); 80 (EN)

Copyright (c) 2021 Annals of Gastroenterology (EN)




*Η εύρυθμη και αδιάλειπτη λειτουργία των διαδικτυακών διευθύνσεων των συλλογών (ψηφιακό αρχείο, καρτέλα τεκμηρίου στο αποθετήριο) είναι αποκλειστική ευθύνη των αντίστοιχων Φορέων περιεχομένου.