Performance and applicability of a first generation single-use duodenoscope: a single-center cohort study

Το τεκμήριο παρέχεται από τον φορέα :
Ελληνική Γαστροεντερολογική Εταιρία   

Αποθετήριο :
Annals of Gastroenterology   

δείτε την πρωτότυπη σελίδα τεκμηρίου
στον ιστότοπο του αποθετηρίου του φορέα για περισσότερες πληροφορίες και για να δείτε όλα τα ψηφιακά αρχεία του τεκμηρίου*



Performance and applicability of a first generation single-use duodenoscope: a single-center cohort study (EN)

Dreesen, Mira
Meert, Wouter
Van Der Merwe, Schalk
Persyn, Diederik
Van Malenstein, Hannah
Vanderschueren, Emma
Laleman, Wim
Schuermans, Annette
Buysschaert, kristof

info:eu-repo/semantics/article
info:eu-repo/semantics/publishedVersion

2022-06-28


Background Despite the standardization and optimization of disinfection protocols, duodenoscope-related infections (DRIs) remain an emerging threat for patients undergoing endoscopic retrograde cholangiopancreatography (ERCP). Single-use duodenoscopes could represent a potential alternative avenue to circumvent the problem of reprocessing and thus risk of exogenous patient-to-patient transmission. The aim of our study was to test the feasibility and technical success rate of a recently made available single-use duodenoscope. Methods We carried out a thorough and standardized evaluation of the usability, performance and safety of a recently developed single-use duodenoscope in 52 consecutive patients scheduled for ERCP in a single center. Outcomes included performance ratings of the single-use duodenoscopes, adverse events (assessed at 3 days and 1 week), and crossover rate to a reusable duodenoscope. Results The ERCP completion rate with a single-use duodenoscope was 90.4%, rising to 94.2% after crossover to reusable duodenoscope. The mean American Society for Gastrointestinal Endoscopy (ASGE) grade was 2.7, with 27 procedures (51.9%) considered as advanced level complexity (ASGE grade 3 & 4). Performance rating found that 94% of the therapeutic treatments were comparable to those using a traditional reusable duodenoscope. Overall satisfaction amounted to 80%. No major adverse events were attributable to the single-use endoscope. Conclusions Single-use duodenoscopes can provide an alternative to avoid the intensive and often inconsistent results of cleaning and disinfection procedures. We confirmed the feasibility, adequate performance characteristics and safety of a recently developed first-generation singleuse duodenoscope over a broad range of ERCP procedures, in terms of both indication and complexity. Keywords Single-use duodenoscope, ERCP, duodenoscope-related infection, performance Ann Gastroenterol 2022; 35 (4): 368-375 (EN)


Αγγλική γλώσσα

Hellenic Society of Gastroenterology (EN)


1792-7463
1108-7471
Annals of Gastroenterology; Volume 35, No 4 (2022); 368 (EN)

Copyright (c) 2022 Annals of Gastroenterology (EN)




*Η εύρυθμη και αδιάλειπτη λειτουργία των διαδικτυακών διευθύνσεων των συλλογών (ψηφιακό αρχείο, καρτέλα τεκμηρίου στο αποθετήριο) είναι αποκλειστική ευθύνη των αντίστοιχων Φορέων περιεχομένου.