A two-layered flow induced by peristaltic waves in a catheterized tube
(EN)
The flow of a two-layered Newtonian fluid induced by peristaltic waves in a
catheterized tube has been investigated. The expressions for the flow characteristicsthe
flow rate, the pressure drop and the friction forces at the tube and catheter wall are
derived. It is found that the pressure drop increases with the flow rate but decreases
with the increasing peripheral layer thickness and a linear relationship between
pressure and flow exists. The pressure drop increases with the catheter size (radius)
and assumes a high asymptotic at the catheter size more that fifty percent of the tube
size. The friction forces at the tube and catheter wall posses characteristics similar to
that of the pressure drop with respect to any parameter. However, friction force at
catheter wall assumes much smaller magnitude than the corresponding value at the
tube wall.
(EN)
*Η εύρυθμη και αδιάλειπτη λειτουργία των διαδικτυακών διευθύνσεων των συλλογών (ψηφιακό αρχείο, καρτέλα τεκμηρίου στο αποθετήριο) είναι αποκλειστική ευθύνη των αντίστοιχων Φορέων περιεχομένου.