Preliminary results of investigations of possible ground deformation structures in the early christian basilica, ancient Lechaion harbour, Corinth, Greece.

This item is provided by the institution :
Geological Society of Greece   

Repository :
Bulletin of the Geological Society of Greece  | ΕΚΤ eJournals   

see the original item page
in the repository's web site and access all digital files if the item*



Preliminary results of investigations of possible ground deformation structures in the early christian basilica, ancient Lechaion harbour, Corinth, Greece. (EN)

Minos-Minopoulos, D.
Dominey-Howes, D.
Pavlopoulos, K.
Lekkas, E.
G., Apostolopoulos

info:eu-repo/semantics/article
info:eu-repo/semantics/publishedVersion

2013-01-21


Η Παλαιοχριστιανική Βασιλική Λεχαίου, Κόρινθος, κατασκευάστηκε στα τέλη του 5ου αι. μ.Χ. στον δυτικό βραχίονα του αρχαίου λιμανιού του Λεχαίου, και σύμφωνα με αρχαιολογικές ανασκαφές καταστράφηκε από την σεισμική δραστηριότητα του 551-552 μ.Χ.. Διάσπαρτα βυθίσματα και υβώματα που παρατηρήθηκαν στο δάπεδο της Βασιλικής αποτελούν ενδεικτικές δομές εδαφικής παραμόρφωσης η οποία πιθανόν να σχετίζεται με ρευστοποίηση εδάφους. Με στόχο την διερεύνηση της στρωματογραφίας και της δομής του υπεδάφους πραγματοποιήθηκαν γεωφυσικές διασκοπήσεις GPR και μετρήσεις αγωγιμότητας του εδάφους κατά μήκος δέκα επιλεγμένων τομών και συσχέτιση τους με τη στρωματογραφία όπως αυτή περιγράφεται από αρχαιολογικά σκάμματα. Τα αποτελέσματα της μελέτης είναι ενδεικτικά δομών παραμόρφωσης των υποκείμενων εδαφικών σχηματισμών με χαρακτηριστικά που επιτρέπουν την συσχέτιση των επιφανειακών δομών που παρατηρήθηκαν στο δάπεδο της Βασιλικής με το φαινόμενο της ρευστοποίησης εδάφους. (EL)
The Early Christian Basilica of Lechaion, Corinth, located on the western jetty of the ancient Lechaion harbour, was constructed during the late 5th century AD and archaeological excavations suggest that it was destroyed by seismic activity during 551-552 AD. Numerous depressions and buckling structures observed on the Basilica floor are indicative of ground deformation structures, likely associated with liquefaction. In an attempt to investigate the subsurface soil structure, and stratigraphy, a GPR survey and horizontal distribution of ground conductivity along ten selected transects was carried out, supplemented by stratigraphic data as described by archaeological trenches. The results of the study revealed subsurface deformation features providing sufficient indications that allow us to suggest that the surface structures observed on the Basilica floor are the surface expression of earthquake-induced ground liquefaction. (EN)


Ρευστοποίηση εδάφους (EL)
Διασκόπηση GPR (EL)
Αγωγιμότητα εδάφους. (EL)
Ground liquefaction (EN)
Ground conductivity (EN)
GPR survey (EN)

Δελτίο της Ελληνικής Γεωλογικής Εταιρίας

English

Geological Society of Greece (EN)


0438-9557
2529-1718
Δελτίο της Ελληνικής Γεωλογικής Εταιρείας; Τόμ. 47 Αρ. 4 (2013): Διεθνές Συνέδριο "Έρευνα και Εκμετάλλευση Ορυκτών Πόρων"; 1769-1778 (EL)
Bulletin of the Geological Society of Greece; Vol. 47 No. 4 (2013): International Congress "Exploration and Exploitation of Mineral Resources"; 1769-1778 (EN)

https://creativecommons.org/licenses/by-nc/4.0
Copyright (c) 2013 D. Minos-Minopoulos, K. Pavlopoulos, Apostolopoulos G., D. Dominey-Howes, E. Lekkas (EN)




*Institutions are responsible for keeping their URLs functional (digital file, item page in repository site)