DIGITAL SIMULATION OF THE STEADY STATE BEHAVIOUR OF A 3 PHI FULL CONTROLLED D. C. DRIVE.

δείτε την πρωτότυπη σελίδα τεκμηρίου
στον ιστότοπο του αποθετηρίου του φορέα για περισσότερες πληροφορίες και για να δείτε όλα τα ψηφιακά αρχεία του τεκμηρίου*



DIGITAL SIMULATION OF THE STEADY STATE BEHAVIOUR OF A 3 PHI FULL CONTROLLED D. C. DRIVE. (EN)

Dratsas, Athanassious (EN)
Kontos, George (EN)

conferenceItem (EN)

2014-03-01T02:40:47Z
1984 (EN)


A digital computer simulation method for the study of the steady state behaviour of a full wave, full controlled 3-phase bridge is presented. In the proposed solution no idealizations for the power supply are made. The solution is based on Kron's method of analysis and tensor theory is used. It must be pointed out that only continuous conduction in both modes of operation - rectifier and inverter - is considered. The main phenomena appearing during both modes of operation are examined and relevant results are obtained, approaching in a satisfactory way the problem. The validity of the method is proved also in the case of the study of such a system. (EN)

DIGITAL SIMULATION (EN)
ELECTRONIC CIRCUITS, BRIDGE (EN)
KRON'S METHOD OF ANALYSIS AND TENSOR THEORY (EN)
ELECTRIC DRIVE (EN)
ELECTRICAL AND MECHANICAL MAGNITUDES OF SYSTEM (EN)
STEADY STATE BEHAVIOR (EN)
THREE PHASE FULL CONTROLLED DC DRIVE (EN)